Products Resources
Software
Contacting
us
What's New
|
 |
|
TRsSim
Software - Change Log:
Vrs 1.32.560 -
March 5, 2008
AI-7280/AI-80
Specific:
1. Display the delay from going off-hook (or line flash)
to the start of the first dialed DTMF digit. The delay
time is displayed on the main control panel as well as the
dialing logs.
2. Add a programmable delay time for the network tone (if
any) configured to start once the TE goes off-hook.
Previously, the tone would start immediately following the
off-hook. AI-5120
Specific:
1. Add a new setting in the 'FSK Detection Settings'
window that optionally ignores FSK data in either the on-hook or
off-hook state.
2. Fix a bug that prevented (under certain situations) a
display update if DTMF warning limits where changed. The
missing display update could have resulted in warnings being
shown when they should not have been (or vice versa).
3. Add the ability to configure the AI-5120 to record data
without the TRsSim software connected. For remote data
collection, the AI-5120 can be configured to output event and
waveform data directly to its USB or RS-232 port on power
up. If the data is recorded to a file (using
'Ai5120logger.exe' or other similar application), the event and
waveform data can be recovered by the TRsSim software.
4. Fix a bug introduced in vrs 1.31 that prevented the
logging and exporting of event data. Scripting:
1. Add various properties and functions to access the
AI-7280/AI-80 dialing log. This log contains DTMF dialed
digits, pulse dialing digits, and line flash information.
2. Add property to modify the delay time from when a TE
goes off-hook to when a network tone is started. |
Vrs 1.31.545 -
January 8, 2008
General:
1. Change the location of where various files are stored
in order to increase compatibility with Windows Vista and allow
for easier sharing between multiple installations of the TRsSim
software.
2. Support loading of configuration and script project
files from the command line.
3. Configuration, Data Recorder, and Script Project files
are only saved in the compressed file format. The older
non-compressed format can still be used when loading files. AI-7280/AI-80
Specific:
1. Fix a bug that prevented the load of a configuration
file if the maximum number of ringing patterns had been reached.
2. Support the use of a 'null' start code for DTMF Caller
ID messages.
3. Support the new features available in version 3
of the AI-7280 firmware. This includes an expanded line voltage,
loop current, and DC ringing offset voltage range. The
added ITU O.41 weighing filter can be used in the 'Signal
Analysis/Generation' mode.
4. Ringing patterns can be specified with a programmable
DC offset voltage.
5. Caller ID ringing can be specified with a programmable
DC offset voltage.
6. Fix a bug that prevented the proper display of Greek
SMS characters.
7. Display a warning icon when: i) the ring
generator output may be clipped based on the wave shape
settings, output level, and DC offset voltage, ii) off-hook loop
current does not match specified loop current due to high loop
resistance and/or low line voltage settings, iii) Caller
ID impairment settings conflict with signaling timing.
8. Add ability to copy existing ringing patterns, tone
definitions, or Caller ID messages when creating a new one. AI-5120
Specific:
1. Fix bug in analysis of FSK waveforms which could cause
a terminal error.
2. Allow waveform analysis on a loaded configuration file
when operating in 'demo' mode. Scripting:
1. Change the script development GUI to a single window
environment.
2. Support multiple project development along with script
controlled project switching.
3. Support device script projects. These script
projects run programs directly on the AI-80/5120/7280 hardware.
4. Modify the operation of the 'Popup Message Window' to
allow detection of selected events while the window is still
visible and not only when it has been closed. Also modify
the operation of the 'IsTopWindow' property. If active,
the window is only 'top' for application and not the entire
desktop. This change prevents conflicts with other
applications and modal or system wide message boxes.
5. Fix bug that caused incorrect 'table' data to be saved
in script project files.
6. Add function to enable or disable the auto-increment
FSK Caller ID parameter feature. |
Vrs 1.27.490 -
January 22, 2007
Scripting:
1. Add script properties and functions giving access to a
PC's serial communication ports.
2. Add script properties and functions for controlling the
playback of a wave file. |
Vrs 1.27.489 -
January 9, 2007
General:
1. Fix setup problem with version 1.27.483. The
previous setup package included an older version of the
AiWBex1.dll by mistake. AI-7280/AI-80
Specific:
1. Provided better support for displaying unicode
characters used in SMS.
2. Modify operation of user defined ringing wave shape
such that the RMS level and DC offset are always normalized
before loading the data points into the AI-7280.
3. Fix bug when generating metering pulses. The
'count' setting was not updated sometimes when the 'continuous'
mode was enabled. AI-5120
Specific:
1. Fix a bug that caused compressed ringing (ring trip
interval) from being detected as pulse dialing digits (under
certain conditions of ringing wave shape, level, and DC offset).
2. Fix a bug that could cause false detection of DTMF, FSK,
or network tones during ringing. |
Vrs 1.27.483 -
November 15, 2005
General:
1. Include the contents of script tables when saving
configuration or script project files.
2. Add option for automatic checks of software or firmware
updates on a regular basis.
3. Improve the speed at which large configuration files
can be loaded or saved. Scripting:
1. Support line continuation. If a script line ends
with the '_' character, the next line is assumed to be part of
the current line.
2. Block commenting. Selecting a block of text and
pressing Ctrl-D will comment the entire text block.
3. Expand the IF-THEN-ELSE structure to include ELSEIF
<expression> THEN statements.
4. Fix documentation mistakes with the Rnd() function and
the Event.Goto.Index() function.
5. Add script properties to the PopUpMsg box for increased
functionality.
6. Add script properties and functions to modify and
control various AI-5120 settings. AI-7280/AI-80
Specific:
1. Fix timing bug that caused an extension to any wait
blocks following FSK data if impairments where enabled.
2. Decode concatenated SMS protocol 1 SUBMIT
messages. Concatenated messages can be read by the
LastSubmit.Message script property. AI-5120
Specific:
1. Measure and report the crest factor when ringing is
detected.
2. Improve sample rate conversion algorithm to minimize
distortion introduced when exporting waveforms with different
sample rates.
3. Allow more than 10 digits to be part of a SDMF Caller
ID message.
4. Check for invalid day/month combinations for Caller ID
date/time parameters. For example, February 30th is not a
valid day/month combination.
5. Remember the scroll bar position when viewing the event
list so when returning to an event list view, the previous
scroll bar position is used.
6. During long ring trip durations, suppress the false
detection of pulse dialed digits.
7. Expand the tone templates to include limits on maximum
level, maximum duration, and a detection mode setting.
8. Support the detection of tone sequences. A
sequence is a series of tone(s) that can occur one after the
other.
9. Improve the display update rate when viewing a large
number of waveforms.
10. Add a setting that enables an adjustable high pass
filter prior to performing any THD+N measurements made during
FSK, DTMF, and CAS/DTAS analysis.
11. Add option to automatically perform the waveform
analysis function on any DTMF digits detected.
12. Double clicking the mouse in the Data Recorder
waveform view causes the mouse mode to toggle between 'select'
and 'pan'.
13. In a new 'Tone Analysis' that finds and analyzes all
tones present in a recorded waveform.
14. Add a 'Quick Setup' window. This window combines
a number of common settings in a single window for each access.
15. Quick waveform record. By clicking the 'record'
status bar icon, the 5120 starts an immediate waveform
recording.
16. Display an warning icon if any event measurements are
outside specified limits, or the waveform analysis reported a
warning condition.
17. If no FSK signal is detected following a manually
initiated analysis, give an option to display the FSK decoder
waveform and any data bytes detected within the waveform.
18. Display FSK byte level errors and framing errors on
the waveform view.
19. Cache event data in order to speed up the event list
display when a large number of events have been captured.
20. Show 'Report' icon for CAS/DTAS events once the
waveform analysis as been performed.
21. Fix bugs in event search: a) incorrect
comparison test with 'DTMF String', b) criteria copy did not
transfer the measurement index field properly. c)
incorrect criteria where selected in the event search drop-down
list if another criteria was deleted. |
Vrs 1.24.395 -
July 6, 2006
General:
1. When adding USB capable devices, dynamically show which
devices are currently connected to the PC.
2. Default location for configuration files is now the '\configs\
sub-directory.
3. Remember the directory a configuration file or script
file was accessed from. Save the directory information
between program runs.
4. If a communication error is encountered with a device,
present an option to attempt a re-connection.
5. Fixed a bug that prevented a switch in the AI-5120's mode
of operation (from TRsSim to Instrument Suite) if multiple USB
devices were connected to the PC.
6. Remember device window positions when performing a
restoration of settings or loading a configuration file (that
requires a device re-load).
7. Prevent two device windows from overlaying exactly on
top of each other when the second device is added. Scripting:
1. Make the LOCAL keyword optional. When declaring
variables, if no variable type is specified, it is assumed to be
local.
2. Allow variable assignments at declaration time for
LOCAL and GLOBAL variables. For example: 'Numeric
TwoPi = 3.1415926 * 2', declares the variable and assigns it in
a single statement.
3. Add properties and functions to read binary and text
files.
4. Add properties and functions to write and control low
level device scripts. AI-7280/AI-80
Specific:
1. Support Japanese NTT Type II CID. A Caller ID
signaling sequence is now included for generating Type II
CID. Note that only the AI-7280 can execute the Type II
signaling sequence.
2. Add a 41h message type for NTT CID. The type
41h message is used for Type II NTT CID. Messages can be
set for auto-selection. This changes the message type
value between 40h and 41h depending if a Type I or Type II CID is
being sent.
3. Add new NTT CID message parameter 'Calling Number
Extended Information'.
4. In 'Signal Analysis & Generation' mode, add a new
action that generates back to back line reversals.
5. In 'Signal Analysis & Generation' mode, add the
ability to write short scripts that execute directly on the
AI-80 or AI-7280.
6. For the AI-7280, use a band pass filter when measuring
the SMS FSK message levels. This fixes a problem where DC
voltage shifts (line reversals or such) close to FSK messages
upset the level meter to such a large degree that timing
measurement accuracy becomes poor. The band pass filter
helps to removes the effect of large DC voltage shifts.
7. Fixed a bug causing a terminal error if more than 25
Caller ID signaling blocks where inserted into a sequence.
8. Display Type II Caller ID 'extension-in-use' check
timing information in the Data Viewer window. In addition,
the ACK start and stop times can be shown when using the AI-7280
(not supported with the AI-80).
9. When configuring a network tone to start upon an
off-hook condition, only update the AI-80 or AI-7280 flash
memory if a change to the tone setting is made.
10. For parameter sweep graphs, limit the minimum vertical
span to 1 dB.
11. Add a new setting for signal generator termination
impedance of 'Source Z'. This setting assumes the line
termination impedance will be exactly the same as the line
source impedance setting.
12. Fixed a bug that occured when deleting CID signaling
elements that have a branch. If the lower portion
was deleted, the branch element above was not correctly modified
to reflect the change.
13. Fixed a bug that caused the TRsSim software to try to
generate a Type I CID (on-hook), when the line state was
off-hook. This occurred when the 'Reset.All' function was
used in a script program and the current line state was
off-hook. AI-5120
Specific:
1. If only a single AI-5120 is connected, default to a new
display view. The 'Docked Window' mode automatically opens
two linked Data Viewer windows that automatically display a list
of detected events in one window and the captured waveforms in
the second window. The windows are automatically resized
to the application window size. This display mode
can be enabled or disabled from a command selection under the 'Window'
menu.
2. Modified CID Summary report view as follows:
a) Lock header to the top of the window.
b) Scroll bar position is not reset when selecting
different CID transmissions.
c) Ensure waveform icon is refreshed in case the
waveform download does
finish until after the
display updates.
d) Add a waveform icon that displays the entire CID
transmission (all elements).
e) If in 'docked window mode', the CID waveforms
are displayed in the 2nd
window.
3. For the FSK waveform analysis, fixed a distortion
measurement error that occurred when the mark level and
frequency could not be measured. In such a case, a warning
message is included in the report.
4. Fixed a bug that could cause an extra channel seizure
bit being reported (for FSK messages).
5. For the event list view, add an option to always 'snap
to last' event. If enabled, once additional events are detected, the
Data Viewer window always ensures they are displayed.
6. Add two tool bar buttons to snap to the next or
previous waveforms. When clicked a search is made for the
next or previous waveform and if found, the waveform(s) are
displayed.
7. Changes to the Navigation bar:
a) Hovering the mouse over a waveform displays a
pop-up of the waveforms.
b) Left clicking on any waveform causes that
waveform to be displayed.
c) Right clicking enters a local panning
mode. Hold the mouse button down
and drag left or right to
pan over a range 10 times the currently displayed
time span.
8. Fixed bug when time shifting waveforms via cursor
positions. The time delta was incorrectly calculated as
B-A instead of A-B.
9. Add two additional cursor commands to move either cursor
A or cursor B to the screen center.
10. Coping and moving waveforms. A new 'Copy &
Float' menu command makes a copy of a selected waveform and
floats it on the screen. As the time scale is panned, the
floating waveform does not move. To move the floating
waveform, click on the center screen icons to move vertically,
horizontally, or in both axis together. To fix the
floating waveform in time and vertical position, select the
'Lock Position' command under the Waveform menu.
11. To toggle the event detection and waveform capture
enable, click the mouse on the green/red light icon on the main
window. This is a shortcut to clicking the 'More' button
and selecting 'Freeze/Resume Detection & Recording'.
12. If more than 5000 events are detected, the 'Event
Find' window can display them in groups of 5000 by using the
drop-down list box at the bottom of the window.
13. The redraw speed of the event list has been greatly
increased. Scrolling now occurs at a much faster rate.
14. Complex event searches can be created. Searches
can specify multiple events with various logical
relationships. In addition, criteria can be added to
event measurements. To define searches, select the
'Event Search Criteria' from the 'Settings' menu. Once
searches are defined, the results can be viewed by selecting
'Search Results' from the 'View' menu.
15. Add the option to measure THD+N from the main window
level meter. It is enabled by selecting 'Measure THD+N'
when the units button is clicked. Once enabled, the
AI-5120 automatically tunes its notch filter to the strongest
signal in the range of 80 to 10000 Hz.
16. For the AC Signal event, add two detection
modes. They are minimum level, and minimum level with
frequency.
17. If the waveform analysis optional component is
enabled, then waveform captures due to AC Signal events will
cause an automatic measurement to be made of the signal's
frequency and level. These measurements are annotated on
the waveform display and shown in the event list. In
addition, the measurements may be exported or logged to a file.
18. Add the option to export waveforms at different sample
rates. |
Vrs 1.22.367 -
December 13, 2005
AI-7280/AI-80
Specific:
1. Correct the units display for pulse dialing 'pps' and
percent break ratio limits. AI-5120
Specific:
1. Support NTT Caller ID service type 0x41.
2. Add a new option in the Data Viewer window 'View' menu
to always show the last waveform captured.
3. Fixed bug that caused line flash, OSI, or ext-in-use check events to be suppressed if DinA, DinB, Ac Signal, Dc Level, or Force Capture events occurred between their start and end times.
4. Fixed bug that caused the Data Viewer window FFT markers to be displayed incorrectly if the waveform start time was in
the hundred's of hours. |
Vrs 1.22.362 -
September 28, 2005
AI-7280/AI-80
Specific:
1. Add a setting to control the FSK modulator starting
phase angle for Caller ID transmissions. Previously the
starting phase angle was fixed at zero degrees. |
Vrs 1.21.361 -
September 26, 2005
General:
1. Fixed bug that caused all pages to be printed when only
a subset was specified. Scripting:
1. Fixed bug that caused table data to be saved within
configuration files. AI-7280/AI-80
Specific:
1. Add a new setting to control the rear panel BNC output
gain for the AI-7280.
2. Include DTMF digit timing information when exporting or
logging dialing data for the AI-7280.
3. Add a new setting to specify the signal level units when exporting or logging data. Units can be either
dBm (default), dBV, or mVrms.
4. Fixed bug that caused invalid Caller ID messages if the
parameter data contained a single quotation mark character.
5. Fixed bug that prevented detection of DTMF digits with a frequency error greater than 1.5% after a change to the detection threshold setting. AI-5120 Specific:
1. Fixed bug in network tone analysis that occurred when very short tone bursts were analyzed. |
Vrs 1.20.356 -
August 24, 2005
General:
1. When saving configuration files, they can be setup to
only load between a specified range of dates. Date
information is verified by using an internet time server. Scripting:
1. A new group of properties and functions can be used to
create tables. These tables may be used to present test
results in a tabular format, or as data arrays for use by script
programs.
2. Fixed bug in Mid() and Asc() functions. These two
functions were broken when error trapping code had been
previously added. AI-7280/AI-80
Specific:
1. Modify the range of non-printable characters used when
creating SMS protocol 1 transfer layer messages. This
fixed a problem when using Chinese windows which may not be able
to display the complete range of ANSI characters.
2. Add a Caller ID setting that adjusts the FSK bit timing
skew.
3. When creating AI-80 stand alone SMS programs, include
the ability to generate a dial tone when the TE goes off-hook in
order to dial the SC and submit a message.
4. Fixed bug that always forced the Advanced Caller ID
option to be enabled when operating in demonstration mode.
5. Lower the minimum DTMF digit detect level to -30 dBm.
6. Fixed bug that prevented network tone frequency and
level characteristics from being updated if the tone was
configured to automatically start upon the TE going off-hook. AI-5120 Specific:
1. Save the DTMF twist level to the output log.
2. Fixed bug in network tone analysis that caused
incorrect data being reported if multiple tone bursts with
different frequency components were detected. |
Vrs
1.18.347 - June 21, 2005
General:
1. The AI-80, AI-7280, or AI-5120 device letter assigned
by TRsSim can be changed in the Hardware Setup window.
2. Reduce communication timeout when establishing a
connection. Scripting:
1. Script editor automatically indents text lines when ENTER is pressed. Also, pressing TAB indents a selected block of text to the next tab stop. Likewise pressing TAB & SHIFT together moves a selected block of text back one tab stop.
2. Add an option in the General Settings window that clears all script logs when script programs are executed. AI-7280/AI-80
Specific:
1. For ETSI Protocol 1 SMS, the Message Generator window now supports the usage of 16 bit reference numbers when concatenating long messages.
2. For ETSI Protocol 1 SMS, allow alpha-numeric addresses. If the type field is set to
a value between D0h and DFh, the address is encoded using the GSM 7-bit character set. If any other type value is used, the address is encoded as semi-octets.
3. Add an option in the Caller ID Signal Settings window that adjusts the time reference point for ACK detection to the end of the ACK signal. By default, the time reference point is the moment the ACK signal is detected. Note, this setting is only applicable when using the AI-7280. AI-5120 Specific:
1. Increases the maximum number of frequencies in a network tone to four and allows a wider frequency range from 300 Hz to 5000 Hz. Note that a single
tone frequency between 800 and 1180 Hz can not be detected. Requires AI-5120 firmware version of 2.01 or greater.
2. When event and waveform capture is off-line, the indicator on the status bar blinks.
|
Vrs
1.17.328 - May 11, 2005
AI-5120 Specific:
1. Supports detection of network tones at a lower signal
level (-36 dBV / tone). |
Vrs
1.16.326 - April 12, 2005
General:
1. Allow control of the TRsSim software via files (cmdin.txt / cmdout.txt). The command syntax is the same as for the remote TCP/IP connection.
2. Add menu command to check for software/firmware version updates.
Scripting:
1. Add scripting support for the AI-5120.
2. Add properties to access the FSK based Caller ID
message type offset and length offset settings.
3. Add Rnd() function for generating random numbers.
4. Add properties and functions to access the ETSI SMS protocol 2 message generator window.
AI-7280/AI-80 Specific:
1. Add wave file playback control element for the Caller ID signaling
sequence.
2. Bug fix: An error in the FSK script conversion routine
prevented the AI-80 (only) from generating the correct FSK message.
The multi-byte BYTE commands were not processed correctly.
3. Add "auto-increment" support for FSK based Caller ID
parameter.
4. Add FSK based Caller ID message type and length offset fields.
5. Add ETSI SMS protocol 2 message generator window.
Similar to what exists for protocol 1, this window simplifies
the task of generating segmented TL messages.
6. For SMS protocol 1, when displaying the contents of the TP-UD field, show the hex values as well as the text if using the GSM 7-bit char set.
AI-5120 Specific:
1. Add option to select the signal level units used to export or log event data. The units can be selected from dBm(600), dBV, or
mVrms.
2. Add the option to have old events and waveforms automatically deleted. The delay time is programmable in various steps from 15 minutes to 1 week.
3. Add the ability to return event and waveform information over a TCP/IP connection.
4. Add the option to resume event detection upon configuration file load.
5. Bug Fix: remove memory leak in waveform analysis
module.
6. Data Recorder window: add two additional digits of timing resolution when using the cursors. Also display 1/|delta|.
7. Add a new event type for "Extension In Use Check".
This may occur during a Type II Caller ID transmissions
following the CAS/DTAS tone, but before the ACK tone.
8. Modify waveform navigation in the Data Recorder window. Add navigation bar at the top showing time relationships between all waveforms captured. Add right mouse click popup menu with view history and moving to
next/previous events & waveforms. Panning mode entered by clicking new mode button, middle mouse click, or right mouse click AND CTRL
button held. When in panning mode, automatically scroll when mouse is moved off the
view port. When scrolling left or right and no waveform data exists at the current view, snap to the next/previous waveform based on the scroll direction.
9. Be able to specify the analysis range for all waveform analysis types (instead of
just DTMF). Now FSK/CAS/DTMF/NT analysis can be performed over a
variable range.
10. Add a new event type for network tone. Common
network tones such as dial, ring back, and busy can now be
detected. Custom templates from 1 to 3 tones can be
specified. Requires AI-5120 firmware version 2.00 or
greater along with the TRsSim Waveform Analysis option.
11. Add an option for adjustable high pass and low pass filters to be
engaged during any waveform analysis type. |
Vrs
1.13.298 - January 17, 2005
General:
1. Support a compressed file format for configuration files
(.cfz) and script project files (.spz). The older
uncompressed file format remains supported, however using the
compressed format greatly reduces the file size. When
using the AI-5120, the waveform capture file is now included
within the compressed file. A separate capture file (.cap)
is no longer produced.
2. Setup package includes an updated USB driver (version
1.6.20).
AI-7280/AI-80 Specific:
1. Bug fix. The DLE character codes within a NTT Caller ID
message were not treated correctly. They should of been
automatically duplicated within the message contents.
2. Reduce the minimum acceptable flash time limit to 50 ms from 100 ms.
This supports testing to shorter flash times. Note, unless
the pulse dialing settings are modified, a short line flash may
be interpreted as a single dialing pulse.
3. Add two Signal I/O options to mute either the BNC audio input or BNC audio output connectors during a Type II (off-hook) Caller ID
transmission (AI-7280 only).
4. Stop performing local syntax checks for USER blocks in the CID signaling sequence. The syntax check prevents using globally defined variables in the USER block, since they are defined elsewhere in the CID signaling program.
5. Improve response time for terminating network tones when a DTMF digit is dialed (assuming
this option is enabled).
The network (dial) tone is now normally terminated before the
first DTMF digit finishes.
6. Support user defined wave shapes for ringing (AI-7280 only).
AI-5120 Specific:
1. DTMF detection and analysis modifications: 1) lower minimum detect level
to -35 dBV, 2) improved ability to detect DTMF in the presence of other tones (ie.
dial tone). Note, requires AI-5120 firmware of 1.05 or
greater. |
Vrs
1.12.290 - November 25, 2004
Scripting:
1. Add properties & functions to modify, add, or remove ringing patterns.
2. Add properties & functions to modify, and, or remove tone definitions.
AI-7280/AI-80 Specific:
1. For ETSI Protocol 1 SMS messages, if the DCS field indicates UCS2 encoding, show the message as text
characters instead of hex bytes.
2. Add options to preserve the telephone interface and signal I/O settings when building an AI-80 standalone SMS program.
3. Upon completion of a parameter sweep (AI-7280 only), save the measurement results to the file
"\log\ParamSweep.txt".
4. Bug fix. When multiple TCP/IP/UCP messages are sent in rapid succession. In sufficient delay was inserted between multiple calls to the TE.
5. Bug fix. When using the AI-7280, the noise
generator would not be enabled for network tones if using the
DTMF or MF modes of operation.
AI-5120 Specific:
1. CAS/DTAS analysis is supported with the Waveform Analysis option.
The analysis extracts the CAS/DTAS tone frequencies, levels,
THD+N, and timing parameters.
2. Add a Caller ID
summary report view (accessed from under the View menu).
This report summarizes the Caller ID transmission details in a
single report. |
Vrs
1.12.285 - November 3, 2004
General:
1. Remote applications can now control the TRsSim software via a TCP/IP link. For information on this feature, view the help file available by selecting the [Help] [Remote Control] menu command.
2. Fixed bug preventing the Edit menu commands working with the script editor window.Scripting:
1. Double clicking a module in the project view window displays the source code module.
2. Add "Save Project" menu command to complement the existing "Save As Project" menu command.
3. Add "Immediate" window (under the "Run" menu). Script commands entered into this window are directly executed. They run in parallel with any other script program execution.
4. Script modules can be linked to external files. This allows other editors to be used with script projects. To link a file to a module, right click the mouse on the module in the "Script Project" window, and select the "Link to File..." command.
5. Expand script editor help list capabilities to: i) Show all help items, ii) Find modules or declarations for
subs/functions/variables/constants/labels, iii) search help list for keywords, iv) disable help list when using
slower PCs.
6. Add options to adjust script execution speed and
whether or not the project should be saved prior to compiling.
7. Add three new properties that can be read to determine if various program options are
enabled (DevA.Options.x).
AI-7280/AI-80 Specific:
1. When changing Caller ID types, the last used signaling and message
selections are automatically selected..
AI-5120 Specific:
1. Listing for FSK related events (Caller ID, SMS) support
different level units (mVrms, dBm, dBV).
2. Lower minimum DTMF level limits to -25 dBV from -20 dBV. |
Vrs
1.11.275 - October 12, 2004
General:
1. Add printing page setup option to specify user defined report title or organization name.
Scripting:
1. Add properties and functions to control all aspects of the
Caller ID signaling sequence.
Expanded and new script groups are Cid.Delay, Cid.Timing, and Cid.Sig.
2. Add Cid.Messages.Fsk.Script.AddLine property and
Cid.Messages.MDMF.Param.Custom function (allows user defined
parameters).
3. Add Sms.Events.Flags property. This read only property returns 1 for
Rx/Tx phantom message events (if Rx message ignored by SM-SC, or
Tx message sent with zero FSK level).
4. Add Reset() functions. Used to return various
program settings to their default values.
5. Add ability to show a user definable list of
items from the pop-up message window. See PopUpMsg.List
properties and functions in the help file.
AI-7280/AI-80 Specific:
1. Change all default Caller ID signaling sequences to
generate only a single ring following
the FSK/DTMF transmission.
2. For ETSI protocol 2 SMS setups, event definition now supports phantom message transmission (SC sends message with zero FSK level), and ignoring
Rx messages (SC ignores the message from the TE). Both of these event options help to simulate event sequences where messages are not received properly (on either side). Sending phantom messages still updates applicable timers, while ignoring
Rx messages does not reset,
start, or stop any applicable timers.
3. Bug fix for AI-7280 FSK decoder filter delay
nodes. Fixes a problem that can cause the unit to miss the
first FSK message after power up.
4. Add new "custom" Caller ID MDMF parameter type. Allows user
defined type, length, and data bytes. This can be used to test unknown or illegal parameters.
Requires Advanced Caller ID option.
5. For Telecordia Caller ID type, use the same set of
available MDMF parameters for both the Call Setup (80h) and VMWI
(82h) message types. Requires Advanced Caller
ID option.
6. Fix bug in Caller ID Signaling window. Element
insert and delete actions did not always modify the signaling
sequence correctly.
AI-5120 Specific:
1. Fix bug preventing the data bytes from being listed when performing a data layer analysis
and the message was not Caller ID or SMS (for example, if receiving less than 3 data bytes). |
|